陆工调整关机流程第一版、优化排气提示
This commit is contained in:
+21
-22
@@ -2079,8 +2079,12 @@ void MainWindow::airPushingProcess()
|
||||
}
|
||||
|
||||
if(sysPara->status.airPushingOnTime >= sysPara->para.airPushDurationSec * 1000){
|
||||
sysPara->devOp->controlViscosityPump(false);
|
||||
sysPara->devOp->controlCycleValve(false);
|
||||
|
||||
if(sysPara->devOp->isViscosityPumpOpen())
|
||||
sysPara->devOp->controlViscosityPump(false);
|
||||
|
||||
if(sysPara->devOp->isCycleValveOpen())
|
||||
sysPara->devOp->controlCycleValve(false);
|
||||
|
||||
if(!sysPara->devOp->isReclaimPumpOpen())
|
||||
sysPara->devOp->controlReclaimPump(true, false);
|
||||
@@ -2225,13 +2229,16 @@ void MySleep(unsigned int msec);
|
||||
* 关机前务必保存参数
|
||||
* */
|
||||
void MainWindow::checkForPowerOff(){
|
||||
if(m_powerOffInProgress)
|
||||
return;
|
||||
|
||||
if(sysPara->status.powerOffAppending){
|
||||
m_powerOffInProgress = true;
|
||||
if(!sysPara->status.selfCheckDone)
|
||||
sysPara->status.selfCheckDone = true;
|
||||
this->setDisabled(true);
|
||||
emit setDisableAll();
|
||||
////////关机时提高转速和回收泵压力,粘度泵和循环阀/////
|
||||
quint16 gearPumpValue_backup = sysPara->para.gearPumpValue;
|
||||
////////关机时通过闭环控制维持压力,控制目标不超过650/////
|
||||
int reclaimPumpPWMWidth_backup = sysPara->para.reclaimPumpPWMWidth;;
|
||||
if(!(sysPara->status.statWarn & WARN_STATUS_INK_WARN))
|
||||
{
|
||||
@@ -2257,17 +2264,11 @@ void MainWindow::checkForPowerOff(){
|
||||
}
|
||||
}
|
||||
sysPara->devOp->controlReclaimTankOpen(true);
|
||||
sysPara->status.isPumpValveControledByHand = true; //停止自动
|
||||
sysPara->status.isPumpValveControledByHand = true; // 阀门保持手动,隔膜泵由关机闭环控制
|
||||
if(sysPara->para.gearPumpEnable ){
|
||||
if(!sysPara->para.flagOfReclaimPumEnable){
|
||||
sysPara->para.gearPumpValue = 360;
|
||||
sysPara->devOp->WriteMoterPump();
|
||||
}
|
||||
else{
|
||||
if(sysPara->para.flagOfReclaimPumEnable)
|
||||
sysPara->devOp->controlReclaimPump(true,false);
|
||||
sysPara->para.gearPumpValue = 0;
|
||||
sysPara->devOp->WriteMoterPump();
|
||||
}
|
||||
// 不再固定输出360,隔膜泵由pressureAdj按关机目标压力闭环调节
|
||||
}
|
||||
else{
|
||||
sysPara->para.reclaimPumpPWMWidth = 95;
|
||||
@@ -2298,7 +2299,10 @@ void MainWindow::checkForPowerOff(){
|
||||
updateTotalCnt(0);
|
||||
sysPara->saveParaToFile(); // 关机前将相关配置保存
|
||||
}
|
||||
// 退出关机压力维持阶段,后续关闭泵阀时禁止隔膜泵再次启动
|
||||
sysPara->status.powerOffAppending = false;
|
||||
sysPara->para.gearPumpValue = 0;
|
||||
sysPara->devOp->WriteMoterPump();
|
||||
if(!TEST_MODE){
|
||||
for(int i=7;i>0;i--)
|
||||
{
|
||||
@@ -2317,7 +2321,8 @@ void MainWindow::checkForPowerOff(){
|
||||
}
|
||||
}
|
||||
emit CloseJd();
|
||||
sysPara->para.gearPumpValue=gearPumpValue_backup;
|
||||
sysPara->para.gearPumpValue = 0;
|
||||
sysPara->devOp->WriteMoterPump();
|
||||
sysPara->para.reclaimPumpPWMWidth = reclaimPumpPWMWidth_backup;
|
||||
sysPara->devOp->controlCompressPump(false);
|
||||
setRunStatus(tr("准备关机......"));
|
||||
@@ -4435,15 +4440,9 @@ void MainWindow::on_pushButton_Reboot_clicked()
|
||||
sysPara->devOp->controlReclaimTankOpen(true);
|
||||
sysPara->status.isPumpValveControledByHand = true; //停止自动
|
||||
if(sysPara->para.gearPumpEnable ){
|
||||
if(!sysPara->para.flagOfReclaimPumEnable){
|
||||
sysPara->para.gearPumpValue = 360;
|
||||
sysPara->devOp->WriteMoterPump();
|
||||
}
|
||||
else{
|
||||
if(sysPara->para.flagOfReclaimPumEnable)
|
||||
sysPara->devOp->controlReclaimPump(true,false);
|
||||
sysPara->para.gearPumpValue = 0;
|
||||
sysPara->devOp->WriteMoterPump();
|
||||
}
|
||||
// 不再固定输出360,由闭环控制维持压力
|
||||
}
|
||||
else{
|
||||
sysPara->para.reclaimPumpPWMWidth = 95;
|
||||
|
||||
Reference in New Issue